Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4416 INSERTION LOSS (Gas-switching tubes) 1. Purpose. The purpose of this test is to determine the loss of power incurred in a transmission line due to the insertion of the tube in the line. 2. Equipment. The equipment for making this measurement shall consist of a signal generator or sweep oscillator, an attenuator, a matched detector, and a meter or calibrated scope. The equipment layout is shown on figure 4416-1. FIGURE 4416-1. Equipment layout for insertion-loss measurements. 3. Procedure. 3.1 Integral cavity.
The insertion loss shall be measured by a transmission method, as shown on figure 4416-1, in which the tube is placed between a matched generator and detector. With the signal generator set at the reference frequency, the tube shall be tuned to resonance as evidenced by a pronounced peak of the output indicator. The dB loss of power at the detector, due to the insertion of the tube in the transmission line, shall be within the limits specified. 3.2 Fixed tuned. With the signal generator set at the reference frequency, the dB loss of power at the detector, due to the insertion of the tube in the transmission line, shall be within the limit(s) specified. See figure 4416-1 for test circuit.
3.3 External cavity. The tube shall be mounted in the specified cavity and placed in the circuit specified on figure 4416-1. With the signal generator set at the reference frequency, a relative power reading at the output detector shall be noted. The tube shall then be replaced by the specified cavity calibrator (dummy tube), and the new output reading recorded. The dB ratio of power at the detector with the calibrator in the cavity, to the power at the detector with the tube in place, shall be within the limit(s) specified. METHOD 4416 4416-1 19 April 1968