Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4421 IGNITOR INTERACTION (TR tubes) 1. Purpose. To measure the increase in insertion loss or change in intrinsic Q of a TR tube resulting from the ignitor electrode discharge. 2. Equipment. See method 4416 and figure 4416-1, or method 4475. An adjustable ignitor supply shall be added. 3. Procedure. 3.1 Insertion loss. The tube shall be placed in the circuit specified in method 4416. With the ignitor current set to the value specified, the increase in insertion loss over the quiescent insertion loss shall not be greater than the amount specified on the TSS. 3.2 Intrinsic Q change.
The tubes shall be placed in the circuit specified in method 4475. With the ignitor current adjusted to the given value, the change in intrinsic Q shall be within the limit(s) specified. METHOD 4421 19 April 1968 4421-1