Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4426 TUNING RANGE (TR tubes) 1. Purpose. To determine if a tunable tube covers the specified tuning range in no less than the specified minimum number of turns of the tuning screw and to check for irregularities in the tuning mechanism within the tuning range. 2. Equipment. The equipment for making this measurement shall consist of a signal generator or sweep oscillator, a frequency meter, an attenuator, a matched detector, and a meter or calibrated oscilloscope. See figure 4426-1 for equipment layout. FIGURE 4426-1. Equipment layout for tuning range measurements. 3. Procedure.

The tube shall be connected between a matched generator and a matched load and the tuner adjusted to one end of the specified frequency range. The tuning mechanism shall be varied around this point to observe any irregularities in the tuning characteristic as illustrated on figure 4426-2. This procedure shall be repeated at the other end of the tuning range. No tube shall require less than the specified number of complete turns of the tuning screw to cover the tuning range. The tuning screw shall be cycled from stop to stop before electrical tests are performed.

3.1 When the tuning control is cycled through its entire range, the cones of the tunes shall not touch as shown by an electrical continuity test when the two cones can be electrically isolated or by visual means when they cannot be electrically isolated. 3.2 With reference to figure 4426-2, the tube shall be rejected if, in addition to the main peak, one or more peaks of the output are present for which A is greater than a 20 degree movement of the tuning knob, or B is greater than 10 percent of the amplitude of the main peak. METHOD 4426 4426-1 19 April 1968