Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 3.2.3 The spike-leakage energy, in ergs, is calculated using the following formula: Ws = ps x ts x 10 -2 Where: ps = Peak power of the spike (in watts). ts = Width of the spike portion (in nanoseconds). 3.2.4 The peak value of the flat portion of the leakage pulse, pf, is obtained as explained in 3.2.2. 4. Recommended usage and precautions. 4.1 When using the procedure given in 3.1.1 through 3.1.3, it is assumed that the spike and flat portions of the leakage pulse are approximately rectangular and the calculations involving the two-pulse method are based on this assumption.
Because broadband (low Q) gas-switching tubes generally have a leakage pulse with a considerable trough following the spike portion, the results obtained by calculation show lower than the true value of spike-leakage energy, and sometimes higher than the true value of flat-leakage power. This procedure is recommended when equipment is not readily available to make the measurements in accordance with the procedures given in 3.2.1 through 3.2.4. 4.2 The procedure given in 3.1.4 is recommended for broadband, waveguide type gas-switching tubes.
The present restrictions on using this method of measurement of spike leakage is the availability of test equipment, particularly pulsed power generators, which will operate with narrow pulses. 4.3 The procedures given in 3.2.1 through 3.2.4 are recommended where small values of spike are encountered with tubes such as TR limiters and crystal protectors. Increased accuracy is obtained when the oscilloscope known as a "sampling scope" is used. 4.4 When testing dual tubes as described in 2.3.4, it is important to use a well-balanced circuit.
The 3 dB hybrid couplers used should have a VSWR of less than 1.10, should split the power evenly to within 0.25 dB, and should have a minimum isolation of 25 dB. METHOD 4452A 18 August 1970 4452-6