Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4456 (OBSOLESCENT) IGNITOR-LEAKAGE RESISTANCE (TR tubes) Ignitor-leakage resistance is the dc resistance between the ignitor electrode and the tube body when the tube is in the deionized state. This resistance shall be within the limit(s) specified. The measurement shall be made after the completion of the leakage power and ignitor tests. METHOD 4456 4456-1 19 April 1968