Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4491 TRANSMITTER-RECEIVER ISOLATION (Dual gas-switching tubes) 1. Purpose. The purpose of this test is to determine how effectively the transmitter is decoupled from the receiver during the reception of a low-power signal at the antenna port. 2. Equipment. The following basic equipment layout, or its equivalent using an electronically swept generator, may be used for this test. FIGURE 4491-1. Equipment layout for transmitter-receiver isolation measurements. 3. Procedure. With the TUT in the circuit, as shown on figure 4491-1, the power in the receiver port, Pr , is measured.
The matched termination at the transmitter port, and the power meter at the receiver port are then interchanged, and the power at the transmitter port, Pt, is measured. The test may also be performed with two matched power meters, one at the transmitter port, and one at the receiver port, allowing Pt and Pr to be read at the same time. 4. Formula. The isolation is then calculated as: Isolation = Pt Pr log 10 Alternativley, if Pr and Pt are measured in dB, Isolation = Pr (dB) - Pt (dB). 5. Precautions.
The 3 dB hybrid couplers used shall have a maximum terminated VSWR of 1.10 over the specified frequency range; split the power evenly to within 0.25 dB; and shall have a minimum isolation of 25 dB. METHOD 4491 19 April 1968 4491-1