Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4494 POSITION OF SHORT (Gas-switching tubes) 1. Purpose. To measure the position of the gas discharge sheath behind the window of the tube with respect to a given reference plane. This is of importance in the design of the waveguide mounting of the tube in a system to minimize the magnitude of the discontinuity that the fired tube introduces into the line. 2. Equipment. FIGURE 4494-1. Equipment layout for position of short measurements. 3. Procedure.
With the equipment shown on figure 4494-1, the rf power in the mainline shall be set for the conditions specified, and the position of the voltage standing wave minimum before the shorting plate shall be determined. The metal shorting plate shall then be replaced by the tube, and the shift in the position of the voltage standing wave minimum shall be within the limit(s) specified. METHOD 4494 4494-1 19 April 1968