Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 4551A LIFE TESTS (Microwave tubes) 1. Purpose. The purposes of a life test are: a. To give a degree of statistical assurance that the failure rate or average life of each tube lot is acceptable. b. To provide information on the average life capability of the tube type. c. To provide information on the physical causes of failure, so that engineering effort can be directed to these areas. The relative importance of these purposes depends on the tube application, and should be considered in selecting the statistical group (A, B, C, D, S, or other) to be specified.
In general, groups A, B, C, and D give greater weight to a. above, and are more appropriate for receiving tubes (including microwave tubes such as reflex klystrons and low-noise low-level TWT's); group S, or other tests involving test durations comparable to the average tube life, give more weight to b. and c. above and are appropriate for power tubes. 2. Definitions. 2.1 Continuous life test. A life test in which all inputs to the tube are applied continuously, except for occasional shutdowns for testing or plant closing. 2.2 Intermittent or cycled life test.
A life test in which the inputs to the tube are switched on and off on a regular schedule (to simulate equipment switching) except for occasional shutdowns for testing or plant closing. 2.3 Load-cycled life test. A life test in which the output load (VSWR or phase or both) is varied cyclically, to simulate the effect of a moving antenna. This may be used in combination with either 2.1 or 2.2. When it is used in combination with 2.2, the load cycling should not be synchronized with the high voltage switching, so that the tube is required, over a period of time, to start against every load condition. If "load cycling" is specified without further qualification, the following shall be used:
Load VSWR 1.5:1 minimum, varied through all phases at a rate of not less than 4 cycles per hour. If manually moved, the standing wave introducer shall be cycled through the four phase positions corresponding to maximum power, minimum power, maximum frequency, and minimum frequency, at least once during the specified life of the tube, spending approximately equal periods of time in each phase position. 3. Procedure. 3.1 The TSS shall specify the life test group, the cycling, if any, the operating level ("oscillation (1)," etc.) and the life test end points. The latter are usually slightly relaxed limits on a few key parameters.
For power tubes, it is usual to specify a power output end point equal to 80 percent of the conformance inspection, part 1, power output limit. 3.2 Intermittent life test. The TSS will specify the schedule in the following form: a. Preheat (heater power) (TBS) 1/ minutes b. Operation (1) (TBS) minutes c. No voltages (TBS) minutes. Operation 3.2 b. may consist of more than one operation condition, in sequence, with a specified time for each. ____________ 1/ TBS = to be specified. METHOD 4551A 4551-1 25 March 1970