Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5201 ELECTRODE CURRENT AND VOLTAGE BREAKDOWN (Cathode-ray tubes) 1. Electrode current. Under the specified test conditions, the electrode current shall be within the limit(s) specified. The light output shall be measured as specified in method 5221. 2. Voltage breakdown.

The maximum rated heater or filament voltage shall be applied with the potential of the control grid at maximum rating with respect to the cathode, and with the instantaneous potential of any part of the heater at its maximum rating with respect to the cathode (when unipotential cathode not internally connected to the heater is used) and with all other voltages equal to zero. Maximum rated heater or filament voltage shall be 7.0 volts for tubes with heater or filament voltage rating of 6.3 10 percent and 2.75 volts for tubes with maximum heater or filament voltage of 2.5 10 percent. There shall be no recurrent breakdown between elements. 3. Voltage breakdown (electrostatic types).

The control grid shall be adjusted for cutoff, and the first and second anodes (and the third anode, when present) set at their maximum rated voltages. There shall be no breakdown between elements. 4. Voltage breakdown (magnetic types). The control grid shall be adjusted for cutoff, and grid No. 2 focusing electrode and anode set at their maximum rated voltages. There shall be no breakdown between elements. METHOD 5201 5201-1 19 April 1968