Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5405 DETERMINATION OF STORAGE SURFACE REFERENCE DIMENSION (Cathode-ray charge storage tubes - electrical output) 1. Purpose. To establish a reproducible standard for dimensional comparison. 2. Procedure. By overscanning the storage surface and viewing the output on a monitor, the boundary of the usable storage surface is identified as an abrupt change in the output. The diameter (or diagonal if rectangular) of the area within this boundary is the storage surface reference dimension.
The dimensions of other characteristics of the storage surface as observed on the monitor are measured with reference to the storage surface reference dimension. METHOD 5405 19 April 1968 5405-1