Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5412 LUMINANCE (light output), VISUAL OUTPUT (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to measure the luminance of a visual output storage tube. It may be measured under different procedures depending on the characteristic of the tube that is to be measured. The TSS shall specify which of the following procedures shall be used. 2. Definitions. a. Luminance is the luminous intensity per unit area on the screen. Unless otherwise specified, it is measured in a direction normal to the faceplate. b.

Saturation level is that level of luminance beyond which no further increase in luminance is produced by additional writing. The tube can be written to saturation level by writing up the entire viewing area with the erase pulse amplitude set at zero and then cutting off the write beam. 3. Equipment. a. A photometer shall be used to measure the luminance of the TUT over a circular area 10 5 mm (approximately .4 .2 inch) in diameter. b. Method B additionally requires a deflection system.

The deflection system shall produce a raster from a linear sawtooth field sweep at a 60 1/ Hz repetition frequency and a 53 1/ microsecond linear sawtooth sweep having a 63.5 1/ microsecond period or as specified in the TSS. c. In method B the writing control circuits shall be adjustable, but once adjusted for this test shall maintain a constant unblanking level during the active periods of the write cycles. d. In method B an erase system shall produce rectangular erase pulses with a width of 0.5 1/ millisecond and a frequency of 60 1/ Hz, synchronized with the linear sawtooth field sweep or as specified in the TSS.

Viewing screen current may be reduced or cut off during the erase period as specified in the TSS. 4.1 Method A. This method is for the measurement of saturation luminance (B S ). 4. Procedures. The TSS shall specify which of the following procedures shall be used. a. Operating conditions shall be as specified in the TSS. b. Without erasing, overscan the screen to write the entire target area to saturation level c. Stop writing. Without changing the operating conditions, wait approximately 10 seconds and measure the saturation luminance(s) at the center of the screen or at the location(s) specified on the TSS. 4.2 Method B.

This method is for the measurement of the dynamic equilibrium luminance (B E ) and is intended primarily for tubes whose applications include TV display. a. Operating conditions shall be as specified in the TSS. b. Without simultaneously erasing, write the entire area specified in the TSS to saturation level. c. Stop writing. Use the erase pulse width and frequency amplitude until the last portion of the entire area specified has just been erased. The erase pulse amplitude found shall be used throughout the remaining test procedure. ____________ 1/ Typically, 525 line television system. METHOD 5412 5412-1 12 December 1972