Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5423 READING TIME, VISUAL OUTPUT (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to measure the time period over which a usable output is obtained during continuous readout. 2. Definitions. Saturation level is that level of luminance beyond which no further increase in luminance is produced by additional writing. The tube can be written to saturation level by writing up the entire viewing area with the erase pulse amplitude set a zero and then cutting off the write beam. 3. Equipment. a.
A photometer shall be used to measure the luminance of the TUT over a circular area 10 5 mm (approximately .4 .2 inch) in diameter. b. A stop watch or other elapsed time indicator shall be used. 4. Procedure. Reading time may be determined by either of the following methods. c. A deflection system shall produce a merged raster on the TUT with linear sawtooth deflections in orthogonal directions. 4.1 Method A. This method measures the time required for an erased display to rise in brightness to a specified percentage of saturation. a. Operating conditions shall be as specified in the TSS. b. Without simultaneously erasing, write the entire usable area to saturation level. Caution:
Do not overdrive the write gun beyond that required to reach saturation level. c. Stop writing. Use a 1-second erase pulse and adjust its amplitude until application of a single pulse to the backing electrode will erase the last portion of the fully written area to the cutoff point. d. Without simultaneously erasing, again write the entire usable area to saturation level. e. Stop writing. Apply a single, 1-second erase pulse of amplitude determined in 4.1c above to the backing electrode. f. Measure and record the time for the first area of the erased display to increase to 30 percent of saturation. 4.2 Method B.
This method measures the time required for a specified degradation in contrast ratio between a written and an unwritten area. a. Operating conditions shall be as specified in the TSS. b. Without simultaneously erasing, write the entire usable area to saturation level. Caution: Do not overdrive the write gun beyond that required to reach saturation level. c. Stop writing. Using a erase pulse of 1-second duration, determine the pulse amplitude necessary to reach the storage target cutoff point. This is accomplished by alternately writing to saturation and erasing, while adjusting the erase pulse amplitude. METHOD 5423 5423-1 12 December 1972