Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 d. Without simultaneously erasing, again write the entire usable area specified in the TSS to saturation level. e. Stop writing. Apply a single, 1-second erase pulse of amplitude determined in 4.2c above to the backing electrode. f. Write a 1-inch by 1-inch (25.4 mm by 25.4 mm) raster to initial luminance level (B 1 ), which is equal to 50 percent of saturation, at the location in the usable area that exhibits the shortest reading time for the operating conditions specified. g. Stop writing. Monitor the luminance level (B 2 ) in a unwritten area .750 inch (19.05 mm) distance from the edge of the written raster. h.
While monitoring (B 1 ) and (B 2 ), calculate the contrast ratio from the formula: 1 B B Contrast ratio = 2 Typically, luminance (B 1 ) and (B 2 ) will both increase during this measurement. 5. Precautions. a. To assure that stray light sources do not significantly affect luminance measurements, the light level recorded by the photometer in the measurement position shall be such that, with the TUT off, the photometer reading does not exceed 3 percent of the TUT luminance value to be measured. b. This test is not applicable to tubes operating in a bistable mode. 6. TSS requirements. a. In addition to the operating conditions for the TUT, the TSS shall specify the following:
(1) Usable area (see 4.1d and 4.2d). (2) Minimum reading time (see 4.2h). (3) The applicable test, method A or B (see 4.1 and 4.2). b. If values other than those specified in this test method are required, the TSS shall specify: Contrast ratio (see 4.2h). METHOD 5423 12 December 1972 5423-2