Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5424 DYNAMIC RANGE, ELECTRICAL OUTPUT (Cathode-ray charge storage tubes) 1. Purpose. The purpose of this test is to determine the dynamic range over which a usable output is obtained. This is a small area measurement which reduces the influence of target shading and major blemishes. Shading and blemish count are the subjects of other test methods. 2. Definitions. a. Dynamic range, peak-to-peak disturbance level is the number of incremental output signal levels, each equal to the peak-to-peak target disturbance at that signal level, that may be obtained between cutoff and saturation. b.

Dynamic range, rms disturbance level is the number of incremental output signal levels, each equal to the rms target disturbance at that signal level, that may be obtained between cutoff and saturation. By common practice, rms disturbance is taken as 20 percent of the peak-to-peak disturbance (see 4k). c. Target disturbance is that type of spurious signal, generated within a tube, which appears as abrupt variations in the amplitude of the output signal. These variations are spatially fixed with reference to the target area. A blemish, a mesh pattern, and moire present in the output are forms of disturbance. Random noise (e.g., thermal circuit noise) is not a form of disturbance. 3.

Equipment. a. The reading and writing deflection system(s) shall produce a rectilinear (e.g., TV) type raster repeated at a rate specified in the TSS. b. External focus and deflection components and their location with respect to the reference line shall be as specified in the TSS. c. The output-signal amplifier shall be linear, compensated for the output impedance of the TUT, and have a frequency response that is flat within 1 dB between frequencies (f 1 ) and (f 2 ), to insure accurate reproduction of the required output signals from the TUT. f 1 = the read scan-line repetition rate (Hz). f 2 = D RJ (MHz). Where: R is the anticipated limiting resolution of the TUT in WRSL/SSRD.

J is the read scan-line length as a fraction of the SSRD. D is the active read scan-line duration in microseconds. SSRD is storage surface reference dimension as determined by method 5405. WRSL is written raster scan line. (It is acceptable to compensate for bandwidth limitations of the amplifier by reducing the reading raster width J). METHOD 5424 5424-1 12 December 1972