Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5426 OPERATION TEST (Vidicons) The purpose of this test method is to illustrate a standardized test setup (camera system) to use when testing vidicon tubes. NOTES: 1. Video system requirements. (a) Bandwidth. The frequency response shall be flat, 1 dB, to a frequency greater than the fundamental frequency generated by scanning the required resolution. (b) Low frequency response. With a square wave input at either line or field rate the tilt shall not exceed 2 percent of the peak-to-peak amplitude. (c) Transient response to a unit step input. The overshoot shall not exceed 2 percent of final step amplitude.
The rise time shall be consistent with the overshoot and frequency response. (d) Linearity. Amplitude nonlinearities shall not exceed 2 percent over the useful dynamic range. (e) Gain. At 50 nA signal current, the processing amplifier shall be capable of providing .50 volt of video plus setup to the monitor at an output impedance of 75 ohms. 2. Camera unit requirements. Both horizontal and vertical scanning linearities shall be within 1.0 percent. 3. Unless otherwise specified, standard EIA television scan shall be used. The raster size shall be specified. FIGURE 5426-1. Block diagram of test equipment. METHOD 5426 5426-1 28 March 1975