Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5427 RASTER BURN AND TARGET QUICK AGE (Vidicons) 1. The tube shall be tested in a camera system with associated monitors as shown on the block diagram of figure 5426-1. 2. Align the tube in accordance with method 5437. 3. Raster burn test. a. With conditions as specified, completely overscan target and adjust Ec1 and Esj until complete target is discharged. b. Cap lens and adjust black level for about 20 percent setup. c. Increase monitor bias until complete target is just visible. d. If a raster burn or image burn is present:

(1) With no light on the tube, adjust horizontal, and vertical camera deflection, Ec3 and focus coil current to just overscan the target. (2) Set the target voltage (Esj) at the specified test condition value and slightly defocus by adjusting Ec3. After the specified Esj value, a lower target voltage is permissible, if burn can be removed. (3) Adjust Ec1 to obtain a complete white circular area on monitor with no distortion or dark areas present. The target current should read between the limit(s) specified. (4) Age target as required if target burns are encountered. e. Repeat steps a, b, and c. f. Reject if raster burn is lighter than surrounding area. Reject for any permanent image burn.

METHOD 5427 28 March 1975 5427-1