Department of Defense MIL-STD-1311C — MIL-STD-1311C Test Methods for Electron Tubes – DoD Standard PDF

Downloaded from https://www.everyspec.com MIL-STD-1311C 31 January 2001 METHOD 5428 SIGNAL UNIFORMITY (Vidicons) 1. The tube shall be tested in a camera system with associated monitors as shown on the block diagram of figure 5426-1. 2. Align the tube in accordance with method 5437. 3. Procedure. a. Set up vidicon for optimum operation as specified for center resolution (method 5429). b. The calibrated light source is adjusted to give 2,856 K 20 K color temperature. c. The lens is replaced with the specified mask. d. The scanning is adjusted to just see all of the edge of the aperture on the monitor and the camera scanning linearity is set to less than 1 percent error. e.

Vary the neutral density filter and the position of the light box on the track to give a signal current of 0.2 microamperes (total signal electrode current minus the dark current.) f. Remove the light from the face of the vidicon and adjust the oscilloscope looking at the horizontal waveform so that the lower portion of the dark current trace lies on the "O" line of the graduated scale on the oscilloscope. Blanking level is set to -20 percent to prevent clipping or compression. Apply light and adjust oscilloscope gain and processor blanking level until the top of the envelope of signal current reaches 100 percent and dark current falls on "O" line of oscilloscope.