US Army Developmental Test Command TOP 1-2-622 — Test Setup #1

Downloaded from https://www.everyspec.com TOP 1-2-622 11 September 2009 c. The bandwidth is the difference between the high and low frequency d. Alpha (the exponential attenuation rate) is calculated by: α = π(Fh – Fl) e. Q (quality factor) is calculated by: Q = π(Fo) π(Fh - Fl) f. Df (Damping factor) is calculated by: Df = 1 2 Q 6. EXAMPLE TECHNICAL ANALYSIS.

From the scalars presented in table E-1, which were generated from the measured EMP induced current the following is known; a) the induced current is at a frequency of 129 MHz, b) the bandwidth is approximately 10 MHz, c) the Q is large and the damping factor is small indicating the signal is over damped and will decay quickly, and d) the amplitude of the induced current was 0.15 Amps.

Therefore, if the component connected to this cable was experiencing EMP induced problems, it could most likely be eliminated by designing a simple low pass filter (or a more complicated filter based on the circuit signal requirements) with an upper cutoff frequency of 119 MHz and which is capable of carrying the normal signal currents plus approximately 0.2 Amperes. E-5