Downloaded from https://www.everyspec.com TOP 01-2-511A 20 November 2013 APPENDIX M. PERSONNEL-BORNE ELECTROSTATIC DISCHARGE (PESD). M.1. APPLICABILITY. a. This Appendix provides general test methods to assess the safety and survivability of the SUT to the effects produced by a PESD. This Appendix is meant to act as a guide and is not a replacement for a test plan. b. The PESD environment is applicable to all subsystems, equipment, ordnance EIDs and firing circuits, including those installed external to aircraft IAW the equipment specification. c. PESD environment testing may be applicable at either or both the equipment system level and the component level IAW the equipment specification.
The PESD environment is applied to points on the SUT which may be contacted by personnel during the different configurations / modes of operation including operations, shipping, storage, loading/un-loading and maintenance. M.2. REQUIREMENTS. a. When exposed to the PESD environment, the SUT (and its platform, if any) shall meet the performance requirements detailed in their equipment specifications and test plan. A typical SUT PESD requirement is as follows. When the SUT is not flight or safety critical, often the “during and” is removed from the performance part of the requirement. b.
The SUT, when in the ground handling, storage, transport, and operational configurations, shall remain safe during and after exposure to the PESD environment, and meet its performance requirements during and after exposure to the PESD environment, with parameters specified by MIL-STD-464C, Paragraphs 5.8.3 and 5.8.4. Discharges shall be to any point on the SUT that may be contacted by personnel during operation, transport, storage, and maintenance. c. The simulated PESD environment is defined in MIL-STD-464C, Paragraph 5.8.3 for Ordnance Systems and 5.8.4 for Electrical and Electronic Systems.
The PESD test pulse parameters, detailed in Tables M-1 and M-2, standardize the PESD pulse and simulate the equivalent circuit of a person from which the electrostatic discharge may take place. TABLE M-1. PESD ENVIRONMENT PARAMETERS FOR ORDNANCE M-1 VOLTAGE CAPACITANCE SERIES RESISTANCE ± 25,000 ± 500 Volts 500 ± 5% pF 500 ± 5% ȍ