Configuration | ADS TcHmiSymbol.ShowRecursively: If a variable has this attribute, it is displayed with all sub-elements in the HMI in the case of whitelisting (e.g. structure or function block with all sub-elements). Variables in the sub-elements that are blacklisted with TcHmiSymbol.Hide are not displayed. TcHmiSymbol.Hide: If a variable has this attribute, it will not be displayed in the HMI in case of blacklisting. All variables without an attribute are displayed. If the attribute is used with a structure, all sub-elements are also hidden in the HMI, even if they are tagged with TcHmiSymbol.Show . TcHmiSymbol.ReadOnly:

If a variable has this attribute, the variable with all sub-elements cannot be written in the HMI. TcHmiSymbol.BLOB: If a variable has this attribute, the data is transferred to the server and the client in binary form (reduction of packet size). The data must be converted in the client itself. Blacklisting overrides whitelisting. With blacklisting, all variables are visible in the HMI, except variables with the attribute TcHmi- Symbol.Hide. With whitelisting, no variables are visible in the HMI except variables with the attributes TcHmiSymbol.Show and TcHmiSymbol.ShowRecursively . Available since version 1.12.

4.3.2.3 Methods and properties | Methods and properties With version 1.12 it is possible to access PLC properties in the HMI and to call PLC methods in the HMI. PLC properties The properties must be made visible in the PLC with an attribute pragma via ADS. {attribute 'monitoring' := 'call'} PROPERTY Prop : BOOL You can then access the property in the TwinCAT HMI. TF2000 40 Version: 1.8.0