PLC API Step response Inputs VAR_INPUT fIn : FLOAT; fManValue : FLOAT; eMode : E_CTRL_MODE; bHold : BOOL; END_VAR VAR_OUTPUT fOut : FLOAT; eState : E_CTRL_STATE; eErrorId : E_CTRL_ERRORCODES; bError : BOOL; END_VAR Outputs Inputs/ outputs VAR_IN_OUT stParams : ST_CTRL_PT2_PARAMS; END_VAR TF4100 103 Version: 2.2.4 Name Type Description fIn FLOAT Input value of the PT2 element fManValue FLOAT Input value that is output in manual mode. eMode E CTRL MODE _ _ Input that specifies the operation mode [} 173] of the function block. bHold BOOL A TRUE at this input will hold the internal state (and therefore also the output) constant at its current value, independently of the input value.
Name Type Description fOut FLOAT Output of the PT2 element eState E CTRL STATE _ _ State of the function block eErrorId E CTRL ERROR _ _ CODES Supplies the error number [} 173] when the output bError is set. bError BOOL Becomes TRUE, as soon as an error occurs.