PLC API 4.2.1.4.16 FB_CTRL_TuTg The function block provides a TuTg transfer element (a dead time delay element) in the functional diagram. Transfer function 1 ( ) 1 g G s K e T s - = Ч + u T s p TF4100 114 Version: 2.2.4 Name Type Description tCtrlCycleTime TIME Cycle time with which the control loop is processed. This must be greater than or equal to the TaskCycleTime. The function block uses this input value to calculate internally whether the state and the output values have to be updated in the current cycle. tTaskCycleTime TIME Cycle time with which the function block is called. If the function block is called in every cycle this corresponds to the task cycle time of the calling task.
fMovingRange Min FLOAT Minimum position of the simulated actuator fMovingRange Max FLOAT Maximum position of the simulated actuator tMovingTime TIME The time required to move the simulated actuator from one stop to the other. tDeadTime TIME Dead time of the simulated actuator