Table 6.3 (continued) 6.3 Switch on and operation The device can perform following functions: • tachometer; • operating time counter. The signals arriving at the counting input of the device are filtered. The filter is characterized by the minimum allowable pulse and pause lengths ( minImp parameter, ms). All pulses and pauses less than the specified duration are perceived as bounce and ignored. The recommended value for this parameter is calculated as follows: where MaxFreqRele is the maximum frequency (up to 100 Hz) of switching a dry contact relay. For input frequencies greater than 100 Hz, set minImp = 10 μs. The principle of operation of this parameter is shown in Figure 6.4 : 1 :
pulse duration and pause duration greater than minImp – the signal is passed through the bounce protection system; 32 Button Operating mode of the device Function Setup Selecting an editable digit when changing a parameter value and entering a password (used with the and buttons)