Appendix A.
Device parameters 56 Parameter Modbus register, HEX Allowed values Data type Notes Network parameters Protocol S.PRO 0x0008 0 – ASCII; 1 – RTU unsigned char Write / Read Default – 1 Baud rate, bps bPS 0x0009 0 – 2400; 1 – 4800; 2 – 9600; 3 – 14400; 4 – 19200; 5 – 28800; 6 – 38400; 7 – 57600; 8 – 115200 unsigned char Write / Read Default – 8 Data word length, bits LEN 0x000A 1 – 8 unsigned char Read Default – 1 Parity PRTY 0x000C 0 – no control (NONE); 1– parity (EVEN); 2 – parity (ODD) unsigned char Write / Read Default – 0 Stop bits Sbit 0x000B 0 – 1 stop bit (1); 1 – 2 stop bits (2) unsigned char Write / Read Default – 0 Device address Addr 0x0006 from 1 to 247 unsigned short Write / Read Default – 16 Response delay, ms rS.dL 0x000D from 0 to 45 unsigned char Write / Read Default – 2