Тексел ТХ01-RS — Appendix A Device parameters

57 Parameter Modbus register, HEX Allowed values Data type Notes Parameters for devices with analog output Analog output mode OUTDAC 0x0031 0 – output is off (0) 1 – directly proportional (1); 2 – inversely proportional (2); 3 – recorder (3) unsigned char Write / Read Default – 3 Setting value U of the analog output udAc 0x0032 0х0033 from 0 to FREQ Unsigned long Write / Read Only for directly proportional mode. Default – 0 Value of the direct proportionality zone dPro 0x0034 0х0035 from 1 to FREQ Unsigned long Write / Read Only for directly proportional mode.

Default – 1 Value of the lower registration limit (U-L) LOR 0x0036 0х0037 from 0 to FREQ Unsigned long Write / Read Only in the recorder mode. Default – 0 Upper registration limit value (U-H) Hir 0x0038 0x0039 from 0 to FREQ Unsigned long Write / Read Only in the recorder mode. Default – 2500 Analog output status when control is disabled OFFdAC 0x003A 0 – the value LdAC(0) is output; 1 – the value HdAC(1) is output unsigned char Write / Read Default – 0