58 Parameter Modbus register, HEX Allowed values Data type Notes Parameters for devices with digital output Signal source for digital output SrCC 0x0013 0 – tachometer measurement result (tACHo); 1 – the value HdAC(LiFE.t) is output unsigned char Write / Read Default – 0 Logic type of digital output OUTDO 0x0014 0 - output control is disabled (the output is transferred to the state defined by the parameter oFFdo) (0); 1 – logic type 1 (reverse hysteresis) (1); 2 – logic type 2 (direct hysteresis) (2); 3 – logic type 3 (direct proportional) (3); 4 – logic type 4 (reverse proportional) (4); unsigned char Write / Read Only for input of the comparator – tachometer (SrCC = tACHo) Default – 0 Digital output trigger dobLK 0x0015 0 – disabled (oFF); 1 – enabled (on) unsigned char Write / Read Default – 0.
When setting the parameter to state on, the digital output retains its last state Digital output delay, s dodELA 0x0016 from 0 to 999 unsigned short Write / Read Default – 0 Setpoint for digital output control UdO 0x0017 0х0018 from 0 to FREQ Unsigned long Write / Read Default – 10 at OUTDO > 0