61 Parameter Modbus register, HEX Allowed values Data type Notes Minimum pulse duration, µs minImp 0х0040 0х0041 from 10 to 999999 Unsigned long Write / Read Default – 10 Password PASS 0x0027 0х0028 from 0 to 999999 Unsigned long Write / Read Default – 0 The measured value of rounds in units corresponding to the value DTTA.
Not displayed on the digital indicator 0x0029 0х002A from 0 to 4294967296 Unsigned long Read only Running hours, s Not displayed on the digital indicator 0х002B 0х002C from 0 to 863999999 Unsigned long Read only State of digital output 1 OST 0x002D 0 – output is off (oFF) 1 – output is on (on) unsigned char Read only State of digital output 2 iSt 0x002E 0 – low level (0); 1 – high level (1) unsigned char Read only Device name DEV 0x0000 0x0001 0x0002 ТН01 __ char[6] Read only Firmware version VER 0x0003 0x0004 0x0005 VХ.ХХ _ char[6] Read only