63 Parameter Modbus register, HEX Allowed values Data type Notes Displacement of the upper limit of the current output. HdAC 0x003E from 1000 to -1000 signed short Write only The desired offset of the DAC code relative to the current is transmitted. Default – 0 Apply current output calibration APPLY 0x003F 0 – do not apply; 1 – apply unsigned char Write only Default – 0