EPSON — Setting the Lane ID

Setting the Lane ID Follow the steps below to set the lane ID manually. When the lane ID is set manually, the value of the bottom byte in the IP address is automatically set to the same as the value of the set lane ID. You can set the printer lane ID manually or through the printer driver. 1 Push the Lane setting button for at least 5 seconds when the printer is in the idle mode. The printer prints the following message and enters the lane ID setting mode. Lane ID Mode Started Current ID: xxx 2 Set the third digit of the lane ID assuming decimal expression by pushing the Self-test button.

Assuming the initial setting value to be 0, the value increases by 1 in the following progression each time the Self-test button is pushed. 0  1  2  3  4  5  6  7  8  9  0 The following Paper Jam LED pattern enables you to confirm the selected value. 500 ms 1.5 s Repeats flashing as many times as the set value 3 Push the Lane setting button to fix the setting. The printer moves on to the setting mode for the next digit. 4 Repeat steps 2 and 3 for the second and then the first digit. After the first digit is set, the printer prints the following message.

Lane ID is xxx Press the Lane button to confirm Press the SelfTest button to cancel If the set lane ID is out of the range of 1-254, the following message is printed. The printer discards the set value and ends the lane ID setting mode. Lane ID Mode Cancel ID Range error ID xxx 44