2. PRINTER SETUP ENGLISH VERSION EO1-33097 2.8 Media Sensor Calibration, Self Print Test, and Dump Mode Utilities 2.8 Media Sensor Calibration, Self Print Test, and Dump Mode Utilities These utilities are used to calibrate the sensitivity of the Feed Gap/Black Mark Sensor, Print out a test with details of the printer settings and set the printer into Dump mode. When changing from one type of media to another, it is necessary to calibrate the media sensors. 1. Turn off the printer, make sure the media is correctly loaded, and close the Top Cover. Note : Do not place a pre-printed area above the media sensor, as doing so disables correct sensor calibration. 2.

Press and hold the [FEED] Button while turning on the printer. 3. Both status lights (LED 1 and LED 2) will light up in the following order: Orange Green Other colour sequences 4. Release the [FEED] button when LED 1 and LED 2 light to match the sensor you want to calibrate. Feed Gap (Transmissive) Sensor: LED 1 green, LED 2 in red. Black Mark (Reflective) Sensor: LED 1 green, LED 2 orange. 5. Press the [FEED] button. The printer will feed the media and perform the sensor calibration. 6. To return to Online operation, turn the printer off, then on again. 2.8.1 Media Sensor Calibration NOTE : The selected sensor used in the last print job is remembered and always used.

The factory default sensor is the Feed Gap Sensor. E2-15