beckhoff TS1110 — 4.1.1 Profiles supported by the TwinCAT Simulation Manager

Tutorials Simulation mode In simulation mode (see Figure 2 [ } 16] ), the simulation PLC is added. All mappings between original PLCs and I/O devices are distorted in such a way that devices to be simulated no longer participate in communication. All functions of the switched off devices that should be available in simulation mode, must be taken over by the simulation PLC. The decoupled I/O devices are now no longer required for the (simulation) mode. Simulated mappings break the mappings to the device and take over the original function. Observer mappings only feed process values into the simulation PLC (the original mapping is not broken). Fig. 3: Figure 2:

TwinCAT system in simulation mode The links / mappings from / to the Simulation PLC can represent local or remote connections, dependant of the location of the Simulation PLC. Simulated (virtual) axes Axes designated as 'simulated' are replaced in simulation mode. This means technically that the encoder of the axis will be replaced by a simulation encoder that is free running (setpoint equals currentPoint). The TwinCAT Simulation Manager persists the settings of the Original-Axis within the Original profile, so that all parameters can be restored when switching back to Original-Mode.

Deactivated devices Devices designated as 'simulated' are deactivated in the simulation profile and don't necessarily to be physically present. The function of the device, insofar as required for the simulation, is taken over by the simulation PLC. TS1110 16 Version: 1.0