beckhoff TS1110 — 6.6 FB_SimIntegral

PLC API VAR_INPUT VAR_INPUT bRun : BOOL; (* 0 = Reset *) fIn : REAL; (* Input for derivative *) END_VAR bRun: Activates the block fIn : Input for derivation VAR_OUTPUT VAR_OUTPUT fOut : REAL; (* Derivative output *) END_VAR fOut : Derived value Requirements 6.6 FB_SimIntegral Integral block The integral block integrates the input value 'fIn' with respect to time. The time difference that elapses between two calls of the block serves as the time base. VAR_INPUT VAR_INPUT bRun : BOOL; (* Integrate 1, Hold 0 *) bReset : BOOL; (* Reset *) XIN : REAL; (* Input for Integral*) X0 : REAL; (* Initial value *) END_VAR TS1110 61 Version:

1.0 Development Environment Target System PLC Libraries to include TwinCAT v2.9.0 Build > 1020 PC (i386) TcSimManager.Lib (Standard.Lib; TcBase.Lib; TcSystem.Lib are included automatically)