Plc Library VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bDone : BOOL; bError : BOOL; nErrorId : UDINT; END_VAR bBusy: The output becomes TRUE when the command is started with bExecute as long as the function block is executing the command. While bBusy is TRUE, no new instructions will be accepted at the inputs. When bBusy becomes FALSE again, the function block is ready for a new command. At the same time one of the outputs bDone or bError is set. bDone: The output becomes true if the command succeeded. bError: The output bError becomes true if an error occurs as the command is executed. nErrorId: Contains the command-specific error code of the most recently executed command.
The error code can be found in the ADS error documentation [ } 38] or in the NC error documentation (error codes above 0x4000). Example The Object Id and Parameter Id needed to unlock and write a new value to a transformation parameter can be read from the Transformation Object in System Manager. VAR bUserExecuteUnlock : BOOL; fbFB_UnlockTrafoParam : FB_UnlockTrafoParam; bUserExecuteWriteParam : BOOL; fbADSWRITE : ADSWRITE; oidTrafo : UDINT := 16#010100B0; (*Trafo object id*) pidTrafo : UDINT := 16#05010020; (*parameter id*) fParamValue :
LREAL; END_VAR fbFB_UnlockTrafoParam( bExecute := bUserExecuteUnlock, oidTrafo := oidTrafo, bBusy=>, bDone=>, bError=>, nErrorId=> ); (*After unlocking new parameter value can be written*) fbADSWRITE( NETID:='' , PORT:= AMSPORT_R0_NCSAF, IDXGRP:=oidTrafo , IDXOFFS:= pidTrafo, TS511x 32 Version: 1.0