beckhoff TS511x — 5.1.6 FB_LockTrafoParam

Plc Library LEN:=SIZEOF(fParamValue) , SRCADDR:= ADR(fParamValue), WRITE:=bUserExecuteWriteParam , TMOUT:= , BUSY=> , ERR=> , ERRID=> ); 5.1.6 FB_LockTrafoParam After changing transformation parameters by using FB_UnlockTrafoParam [ } 31] , the Function Block FB_LockTrafoParam locks the transformation parameters again, so they cannot be written anymore. VAR_INPUT VAR_INPUT bExecute : BOOL; oidTrafo : UDINT; END_VAR bExecute: The command is triggered by a rising edge at this input. oidTrafo: Object-ID of the kinematic transformation object. See example [ } 33] below. VAR_OUTPUT VAR_OUTPUT bBusy : BOOL; bDone : BOOL; bError : BOOL; nErrorId : UDINT; END_VAR bBusy:

The output becomes TRUE when the command is started with bExecute as long as the function block is executing the command. While bBusy is TRUE, no new instructions will be accepted at the inputs. When bBusy becomes FALSE again, the function block is ready for a new command. At the same time one of the outputs bDone or bError is set. bDone: The output becomes true if the command succeeded. bError: The output bError becomes true if an error occurs as the command is executed. nErrorId: Contains the command-specific error code of the most recently executed command. The error code can be found in the ADS error documentation [ } 38] or in the NC error documentation (error codes above 0x4000).

Example Scara Transformation Example Object Id TS511x 33 Version: 1.0