beckhoff TS511x — 6.2.3 Group Errors

Error Codes TS511x 58 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 428C 17036 Monitoring "A command with activation position cannot fully be performed because the remaining path is too short"A command with activation position (threshold) like "reach a new velocity at a position" can be just partially executed because the path from the actual position to the activation position is too short. 428D 17037 Monitoring "Illegal decouple type when decoupling a slave axis" The decouple and restart command contains an invalid decouple type.

428E 17038 Monitoring "Illegal target velocity when decoupling a slave axis" The decouple and restart command contains an illegal target velocity [1 428F 17039 Monitoring "The command new dynamic parameter cannot be performed since this would require a new target velocity"Das Kommando zum Aktivieren neuer Dynamikparameter wie Beschleunigung, Verzögerung und Ruck kann nicht durchgeführt werden, da dies eine neue beauftragte Fahrgeschwindigkeit erfordern würde. This situation can occur, for example, if the axis is near the target position in an accelerated state and the dynamics parameter are chosen softer.

4290 17040 Monitoring "A command with activation position cannot be performed because the axis is already in the brake phase" A command with activation position (threshold) e.g. "reach new velocity at position" cannot be performed because the axis is already in the brake phase and the remaining path from the actual position to the activation position is too short. 4291 17041 Monitoring "Decouple routine of slave axis doesn't return a valid solution" Internal jerk scaling of decouple routine cannot evaluate a valid solution (decoupling slave axis and transform to master axis).

The command is rejected because velocity can become too high, a reversal of movement can occur, or the target position can be passed. 4292 17042 Monitoring "Command not be executed because the command buffer is full filled" The command is rejected because the command buffer is full filled. 4293 17043 Internal "Command is rejected due to an internal error in the Look Ahead" (INTERNAL ERROR) The command is rejected due to an internal error in the "look ahead". 4294 17044 Monitoring "Command is rejected because the segment target velocity is not realized" The command is rejected, because the new target segment velocity Vrequ is not realizable and an internal optimizing is impossible.

4295 17045 Monitoring "Successive commands have the same final position" Successive commands have the same final position. So the moving distance is zero. 4296 17046 Monitoring "Logical positioning direction is inconsistent with the direction of the buffer command" In the extended buffer mode, where the actual end position is replaced by the new buffer start position, the logical positioning direction is inconsistent with the direction of the buffer command (=> contradiction).

A buffered command (BufferMode, BlendingLow, BlendingPrevious, BlendingNext, BlendingHigh) is rejected with error 0x4296 if the command is using the Beckhoff specific optional BlendingPosition but the blending position is located beyond the target position of the previous motion command.