Error Codes TS511x 59 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 4297 17047 Monitoring "Command is rejected because the remaining positioning length is to small" The command is rejected because the remaining path length is too small. E.g. when the buffer mode is used and the remaining positioning length in the actual segment is too small for getting the axis in a force free state or to reach the new target velocity at the change of segment. 429A 17050 Function Restart has Failed There is already a motion command within the PTP command buffer and a further new motion command that should have modified the current motion command by restart has failed.
429B 17051 Monitoring „collect error for invalid start parameters“ This error refers to a wrong parameterization of the user (collect error). E. g. dynamic parameters like Velo, Acc or Dec could be equal or less than zero. Or following errors: - BaseFrequence 200 - BaseAmplitude = 1/(2*CycleTime) 429C 17052 Monitoring "Reference cam is not found" During the referencing process for an axis it is moved in the direction of the referencing cam. This reference cam, however, was not found as expected (=> leads to the abortion of the referencing procedure).
429D 17053 Monitoring "Reference cam became not free" During the referencing process for an axis it is moved in the direction of the referencing cam, and is only stopped again when the cam signal is reached. After the axis has also come to a physical standstill, the axis is subsequently started regularly from the cam again. In this case, the reference cam did not become free again as expected when driving down (=> leads to the abortion of the referencing procedure).
429E 17054 Monitoring "IO sync pulse was not found (only when using hardware latch)" If the hardware latch is activated, a sync pulse (zero pulse) is expected to be found and a sync event triggered following the expiry of a certain time or a certain distance. If this is not the case, the reaction is an error and the abortion of the referencing procedure. 429F 17055 Function The Used Buffer Mode is Unknown or not Supported in this Context The buffer mode used for a PTP command (e.g. ABORTING, etc.) is unknown or not supported in this context.
42A0 17056 Internal "Group/axis consequential error" Consequential error resulting from another causative error related to another axis within the group. Group/axis consequential errors can occur in relation to master/slave couplings or with multiple axis interpolating DXD groups. If, for instance, it is detected that the following error limit of a master axis has been exceeded, then this consequential error is assigned to all the other master axes and slave axes in this group.