beckhoff TS511x — 6.2.4 Axis Errors

Error Codes 6.2.4 Axis Errors TS511x 65 Version: 1.0 Error(Hex) Error(Dec) Error Type Description In this connection it is about a customer specific monitoring function. Error(Hex) Error(Dec) Error Type Description 4300 17152 Parameter "Axis ID not allowed" The value for the axis ID is not allowed, e.g. because it has already been assigned, is less than or equal to zero, is greater than 255, or does not exist in the current configuration. Value range: [1 ... 255] Unit: 1 4301 17153 Parameter "Axis type not allowed" The value for the axis type is unacceptable because it is not defined. Type 1: Servo Type 2: Fast/creep Type 3: Stepper motor Value range: [1 ... 3] Unit:

1 4306 17158 Parameter "Slow manual velocity not allowed" The value for the slow manual velocity is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4307 17159 Parameter "Fast manual velocity not allowed" The value for the fast manual velocity is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4308 17160 Parameter "High speed not allowed" The value for the high speed is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4309 17161 Parameter "Acceleration not allowed" The value for the axis acceleration is not allowed. Value range: [0.0, 1000000.0] Unit: e.g. m/s/s 430A 17162 Parameter "Deceleration not allowed" The value for the axis deceleration is not allowed.

Value range: [0.0, 1000000.0] Unit: e.g. m/s/s 430B 17163 Parameter "Jerk not allowed" The value for the axis jerk is not allowed. Value range: [0.0, 1000000.0] Unit: e.g. m/s/s/s 430C 17164 Parameter "Delay time between position and velocity is not allowed" The value for the delay time between position and velocity ("idle time compensation") is not allowed. Value range: [0, 0.1] Unit: s 430D 17165 Parameter "Override-Type not allowed" The value for the velocity override type is not allowed. Type 1: With respect to the internal reduced velocity (default value) Type 2: With respect to the original external start velocity Value range: [1 ... 4] Unit: 1 430E 17166 Parameter "NCI:

Velo-Jump-Factor not allowed" The value for the velo-jump-factor ("VeloJumpFactor") is not allowed. This parameter only works for TwinCAT NCI. Value range: [0, 1000000] Unit: 1