Error Codes TS511x 66 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 430F 17167 Parameter "NCI: Radius of tolerance sphere for the auxiliary axes is invalid" It was tried to enter an invalid value for the size of the tolerance sphere. This sphere affects only auxiliary axes! Value range: [0, 1000] Unit: e.g. mm 4310 17168 Parameter "NCI: Value for maximum deviation for the auxiliary axes is invalid" It was tried to enter an invalid value for the maximum allowed deviation. This parameter affects only auxiliary axes! Value range: [0, 10000] Unit: e.g.
mm 4312 17170 Parameter "Referencing velocity in direction of cam not allowed" The value for the referencing velocity in the direction of the referencing cam is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4313 17171 Parameter "Referencing velocity in sync direction not allowed" The value for the referencing velocity in the direction of the sync pulse (zero track) is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4314 17172 Parameter "Pulse width in positive direction not allowed" The value for the pulse width in the positive direction is not allowed (pulsed operation). The use of the pulse width for positioning is chosen implicitly through the axis start type.
Pulsed operation corresponds to positioning with a relative displacement that corresponds precisely to the pulse width. Value range: [0.0, 1000000.0] Unit: e.g. mm 4315 17173 Parameter "Pulse width in negative direction not allowed" The value for the pulse width in the negative direction is not allowed (pulsed operation). The use of the pulse width for positioning is chosen implicitly through the axis start type. Pulsed operation corresponds to positioning with a relative displacement that corresponds precisely to the pulse width. Value range: [0.0, 1000000.0 Unit: e.g.
mm 4316 17174 Parameter "Pulse time in positive direction not allowed" The value for the pulse width in the positive direction is not allowed (pulsed operation). Value range: [0.0, 600.0] Unit: s 4317 17175 Parameter "Pulse time in negative direction not allowed" The value for the pulse width in the negative direction is not allowed (pulsed operation). Value range: [0.0, 600.0] Unit: s 4318 17176 Parameter "Creep distance in positive direction not allowed" The value for the creep distance in the positive direction is not allowed. Value range: [0.0, 100000.0] Unit: e.g.
mm 4319 17177 Parameter "Creep distance in negative direction not allowed" The value for the creep distance in the negative direction is not allowed. Value range: [0.0, 100000.0] Unit: e.g. mm 431A 17178 Parameter "Braking distance in positive direction not allowed" The value for the braking distance in the positive direction is not allowed. Value range: [0.0, 100000.0] Unit: e.g. mm