beckhoff TS511x — 6.2.4 Axis Errors

Error Codes TS511x 67 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 431B 17179 Parameter "Braking distance in negative direction not allowed" The value for the braking distance in the negative direction is not allowed. Value range: [0.0, 100000.0] Unit: e.g. mm 431C 17180 Parameter "Braking time in positive direction not allowed" The value for the braking time in the positive direction is not allowed. Value range: [0.0, 60.0] Unit: s 431D 17181 Parameter "Braking time in negative direction not allowed" The value for the braking time in the negative direction is not allowed. Value range: [0.0, 60.0] Unit:

s 431E 17182 Parameter "Switching time from high to low speed not allowed" The value for the time to switch from high to low speed is not allowed. Value range: [0.0, 60.0] Unit: s 431F 17183 Parameter "Creep distance for stop not allowed" The value for the creep distance for an explicit stop is not allowed. Value range: [0.0, 100000.0] Unit: e.g. mm 4320 17184 Parameter "Motion monitoring not allowed" The value for the activation of the motion monitoring is not allowed. Value range: [0, 1] Unit: 1 4321 17185 Parameter "Position window monitoring not allowed" The value for the activation of the position window monitoring is not allowed. Value range: [0, 1] Unit:

1 4322 17186 Parameter "Target window monitoring not allowed" The value for the activation of target window monitoring is not allowed. Value range: [0, 1] Unit: 1 4323 17187 Parameter "Loop not allowed" The value for the activation of loop movement is not allowed. Value range: [0, 1] Unit: 1 4324 17188 Parameter "Motion monitoring time not allowed" The value for the motion monitoring time is not allowed. Value range: [0.0, 600.0] Unit: s 4325 17189 Parameter "Target window range not allowed" The value for the target window is not allowed. Value range: [0.0, 10000.0] Unit: e.g. mm 4326 17190 Parameter "Position window range not allowed" The value for the position window is not allowed.

Value range: [0.0, 10000.0] Unit: e.g. mm 4327 17191 Parameter "Position window monitoring time not allowed" The value for the position window monitoring time is not allowed. Value range: [0.0, 600.0] Unit: s 4328 17192 Parameter "Loop movement not allowed" The value for the loop movement is not allowed. Value range: [0.0, 10000.0] Unit: e.g. mm 4329 17193 Parameter "Axis cycle time not allowed" The value for the axis cycle time is not allowed. Value range: [0.001, 0.1] Unit: s