beckhoff TS511x — 6.2.5 Encoder Errors

Error Codes TS511x 75 Version: 1.0 Error(Hex) Error(Dec) Error Type Description encoder is invalid. E.g. this value is used for axis reference sequence (calibration) with the reference mode "Software Sync". Value range: [0x0000000F, 0xFFFFFFFF] Unit: 1 4427 17447 Parameter Parameter Dead Time Compensation Mode (Encoder) is Invalid The parameter for the mode of dead time compensation at the NC encoder is invalid (OFF, ON with velocity, ON with velocity and acceleration). Range of values: [0, 1, 2] Unit: 1 4428 17448 Parameter Parameter “Control Bits of Dead Time Compensation” (Encoder) is Invalid The parameter for the control bits of dead time compensation at the encoder is invalid (e.g.

relative or absolute time interpretation). Range of values: [>0] Unit: 1 4429 17449 Parameter Parameter “Time Related Shift of Dead Time Compensation Mode” (Encoder) is Invalid The parameter for time related shift of dead time compensation (time shift in nanoseconds) at the encoder is invalid. Range of values: [-1.0E9 .. 1.0E9] Unit: ns 4430 17456 Function "Hardware latch activation (encoder)" Activation of the encoder hardware latch was implicitly initiated by the referencing procedure. If this function has already been activated but a latch value has not yet become valid ("latch valid"), another call to the function is refused with this error.

4431 17457 Function "External hardware latch activation (encoder)" The activation of the external hardware latch (only available on the KL5101) is initiated explicitly by an ADS command (called from the PLC program of the Visual Basic interface). If this function has already been activated, but the latch value has not yet been made valid by an external signal ("external latch valid"), another call to the function is refused with this error. 4432 17458 Function "External hardware latch activation (encoder)" If a referencing procedure has previously been initiated and the hardware still signals a valid latch value ("latch valid"), this function must not be called.

In practice, however, this error can almost never occur. 4433 17459 Function "External hardware latch activation (encoder)" If this function has already been initiated and the hardware is still signaling that the external latch value is still valid ("extern latch valid"), a further activation should not be carried out and the commando will be declined with an error (the internal handshake communication between NC and IO device is still active). In that case the validity of the external hardware latch would immediately be signaled, although the old latch value would still be present.

4434 17460 Monitoring "Encoder function not supported" An encoder function has been activated that is currently not released for use, or which is not even implemented. 4435 17461 Monitoring „Encoder function is already active“ An encoder function can not been activated because this functionality is already active.