Error Codes TS511x 76 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 4440 17472 Initialization "Encoder initialization" Encoder has not been initialized. Although the axis has been created, the rest of the initialization has not been performed (1. Initialization of axis I/ O, 2. Initialization of axis, 3. Reset axis). 4441 17473 Address "Axis address" The encoder does not have an axis, or the axis address has not been initialized. 4442 17474 Address "I/O input structure address" The drive does not have a valid I/O input address in the process image. 4443 17475 Address "I/O output structure address" The encoder does not have a valid I/O output address in the process image.
4450 17488 Monitoring "Encoder counter underflow monitoring" The encoder's incremental counter has underflowed. 4451 17489 Monitoring "Encoder counter overflow monitoring" The encoder's incremental counter has overflowed. 4460 17504 Monitoring "Minimum Software Position Limit (Axis Start)" While monitoring of the minimum software position limit is active, an axis start has been performed towards a position that lies below the minimum software position limit.
4461 17505 Monitoring "Maximum Software Position Limit (Axis Start)" While monitoring of the maximum software position limit is active, an axis start has been performed towards a position that lies above the maximum software position limit. 4462 17506 Monitoring "Minimum Software Position Limit (Positioning Process)" While monitoring of the minimum software position limit is active, the actual position has fallen below the minimum software position limit. In case of servo axes, which are moved continuously, this limit is expanded by the magnitude of the parameterized following error position window.
4463 17507 Monitoring "Maximum Software Position Limit (Positioning Process)" While monitoring of the maximum software position limit is active, the actual position has exceeded the maximum software position limit. In case of servo axes, which are moved continuously, this limit is expanded by the magnitude of the parameterized following error position window. 4464 17508 Monitoring „Encoder hardware error“ The drive resp. the encoder system reports a hardware error of the encoder. An optimal error code is displayed in the message of the event log.
4465 17509 Monitoring „Position initialization error at system start“ At the first initialization of the set position was this for all initialization trials (without over-/under-flow, with underflow and overflow ) out of the final position minimum and maximum. 4466 17510 Monitoring Invalid IO data for more than n subsequent NC cycles (encoder) The axis (encoder) has detected for more than n subsequent NC cycles (NC SAF task) invalid encoder IO data (e.g. n=3). Typically, regarding an EtherCAT member it is about a Working Counter Error (WcState) what displays that data transfer between IO device and controller is disturbed.
If this error is set for a longer period of time continuously, this situation can lead to losing the axis reference (the “homed” flag will be reset and the encoder will get the state “unreferenced”). Possible reasons for this error: An EtherCAT slave may have left its OP state or there is a too high real time usage or a too high real time jitter. 4467 17511 Monitoring Invalid Actual Position (Encoder)