Error Codes 6.2.6 Controller Errors TS511x 77 Version: 1.0 Error(Hex) Error(Dec) Error Type Description The IO device delivers an invalid actual position (for CANopen/CoE look at bit 13 of encoder state “TxPDO data invalid” or “invalid actual position value”). 4468 17512 Monitoring Invalid IO Input Data (Error Type 1) The monitoring of the “cyclic IO input counter” (2 bit counter) has detected an error. The input data has not been refreshed for at least 3 NC SAF cycles (the 2 bit counter displays a constant value for multiple NC SAF cycles, instead of incrementing by exactly one from cycle to cycle).
4469 17513 Monitoring Invalid IO Input Data (Error Type 2) The monitoring of the “cyclic IO input counter” (2 bit counter) has detected an error. The quality of input data based on this two bit counter is not sufficient (there is here a simple statistic evaluation that evaluates GOOD cases and BAD cases and in exceeding a special limit value leads to an error). 4470 17520 Monitoring "SSI transformation fault or not finished" The SSI transformation of the FOX 50 module was faulty for some NC- cycles or did not finished respectively.
44A2 17570 Monitoring "ENCERR ADDR CONTROLLER" _ _ 44A3 17571 Monitoring "ENCERR INVALID CONTROLLERTYPE" _ _ Error(Hex) Error(Dec) Error Type Description 4500 17664 Parameter "Controller ID not allowed" The value for the controller ID is not allowed, e.g. because it has already been assigned, is less than or equal to zero, or is greater than 255. Value range: [1 ... 255] Unit: 1 4501 17665 Parameter "Controller type not allowed" The value for the controller type is unacceptable because it is not defined. Type 1: P- controller (position) . . . Type 7: High/low speed controller Type 8: Stepper motor controller Type 9: Sercos controller Value range: [1 ... 8] Unit:
1 4502 17666 Parameter "Controller operating mode not allowed" The value for the controller operating mode is not allowed. Value range: [1] Unit: 1 4503 17667 Parameter "Weighting of the velocity pre-control not allowed" The value for the percentage weighting of the velocity pre-control is not allowed. The parameter is pre-set to 1.0 (100%) as standard. Value range: [0.0 ... 1.0] Unit: % 4504 17668 Parameter "Following error monitoring (position) not allowed" The value for the activation of the following error monitoring is not allowed. Value range: [0, 1] Unit:
1 4505 17669 Parameter "Following error (velocity) not allowed" The value for the activation of the following error monitoring (velocity) is not allowed. Value range: [0, 1] Unit: 1 4506 17670 Parameter "Following error window (position) not allowed" The value for the following error window (maximum allowable following error) is not allowed. Value range: [0.0, 10000.0] Unit: e.g. mm