beckhoff TS511x — 6.2.6 Controller Errors

Error Codes TS511x 78 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 4507 17671 Parameter "Following error filter time (position) not allowed" The value for the following error filter time (position) is not allowed. Value range: [0.0, 600.0] Unit: s 4508 17672 Parameter "Following error window (velocity) not allowed" The value for the following error window (velocity) is not allowed. Value range: [0.0, 10000.0] Unit: e.g. m/min 4509 17673 Parameter "Following error filter time (velocity) not allowed" The value for the following error filter time (velocity) is not allowed. Value range: [0.0, 600.0] Unit:

s 450A 17674 Parameter “Controller Output Limitation” Improper The value for output limitation of the controller at the overall setpoint quantity is improper. The presetting amounts to 0.5 (50 percent). Typically, this parameter is at work if to the motion controller device the velocity interface has been parameterized and the NC performs position control of the position on the controller. 4510 17680 Parameter "Proportional gain Kv or Kp (controller) not allowed" position The value for the proportional gain (Kv factor or Kp factor) is not allowed. Value range: [0.0, 10000.0] Unit: e.g.

mm/s/mm 4511 17681 Parameter "Integral-action time Tn (controller) not allowed" position The value for the integral-action time is not allowed (I proportion of the PID T1 controller). Value range: [0.0, 60.0] Unit: s 4512 17682 Parameter "Derivative action time Tv (controller) not allowed" position The value for the derivative action time is not allowed (D proportion of the PID T1 controller). Value range: [0.0, 60.0] Unit: s 4513 17683 Parameter "Damping time Td (controller) not allowed" position The value for the damping time is not allowed (D proportion of the PID T1 controller). Suggested value: 0.1 * Tv Value range: [0.0, 60.0] Unit:

s 4514 17684 Function "Activation of the automatic offset compensation not allowed" Activation of the automatic offset compensation is only possible for certain types of controller (with no I component). 4515 17685 Parameter "Additional proportional gain Kv or Kp (controller) not allowed" position The value for the second term of the proportional gain (Kv factor or Kp factor) is not allowed. Value range: [0.0, 10000.0] Unit: e.g. mm/s/mm 4516 17686 Parameter "Reference velocity for additional proportional gain Kv or Kp (controller) not allowed" position The value for the reference velocity percentage data entry, to which the additional proportional gain is applied, is not allowed.

The standard setting for the parameter is 0.5 (50%). Value range: [0.0 ... 1.0] Unit: % 4517 17687 Parameter "Proportional gain Pa (proportion) not allowed" acceleration The value for the proportional gain (Pa factor) is not allowed. Value range: [0.0, 1000000.0] Unit: s 4518 17688 Parameter "Proportional gain Kv (velocity controller) not allowed" The value for the proportional gain (Kv factor) is not allowed. Value range: [0.0, 10000.0] Unit: 1