Error Codes TS511x 79 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 4519 17689 Parameter “Reset time Tn (velocity controller) not allowed” The value for the integral-action time is not allowed (I proportion of the PID T1 controller). Value range: [0.0, 60.0] Unit: s 451A 17690 Parameter Reserved Reserved, currently not used. 451B 17691 Parameter Reserved Reserved, currently not used. 451C 17692 Parameter “Velocity Filter Time” Improper The parameter for velocity filter time in seconds is improper (P-T1 filter).
This filter can be used within the NC for filtering an actual velocity or a velocity difference (velocity error = setpoint velocity - actual velocity) in special NC controllers (e.g. within the torque interface). Range of values: [0.0, 60.0] Unit: s 451D 17693 Parameter „Dead zone not allowed“ The value for the dead zone from the position error or the velocity error (system deviation) is not allowed (only for complex controller with velocity or torque interface). Value range: [0.0, 10000.0] Unit: mm resp. mm/s 451F 17695 Parameter “Proportionality Factor Kcp” Improper The parameter for the “proportional factor Kcp” of the slave coupling differential control is improper. Range of values:
[0.0, 10000.0] Unit: e.g. mm^2/mm 4520 17696 Parameter ”Rate time Tv (velocity controller) not allowed” The value for the derivative action time is not allowed (D proportion of the PID T1 controller). Value range: [0.0, 60.0] Unit: s 4521 17697 Parameter "Damping time Td (velocity controller) not allowed" The value for the damping time is not allowed (D proportion of the PID T1 controller). Suggested value: 0.1 * Tv Value range: [0.0, 60.0] Unit: s 4522 17698 Parameter “Limitation of the I Part” Improper The parameter for limiting the I part of a PI or PID controller is improper. This inner state quantity can be limited in percent (1.0 refers to 100 percent). Range of values: [0.0 ..
1.0] Unit: % 4523 17699 Parameter “Limitation of the D Part” Improper The parameter for limitation of the D part of a PI or PID controller is improper. This inner state quantity may be limited in percent (1.0 refers to 100 percent). Range of values: [0.0 .. 1.0] Unit: % 4524 17700 Parameter Parameter “Switching Off the I Part During Motion” is Improper The boolean parameter for switching off the I part during an active positioning is improper. Range of values: [0, 1] Unit: 1 4525 17701 Parameter Parameter “Filter Time for P-T2 Filter” Improper The time T0 in seconds is as filter time for the velocity controller P-T2 element improper.
The filter time has to be smaller than twice the NC-SAF cycle time.