beckhoff TS511x — 6.2.6 Controller Errors

Error Codes TS511x 80 Version: 1.0 Error(Hex) Error(Dec) Error Type Description Range of values: [0.0, 60.0] Unit: s 4526 17702 Parameter Velocity Observer: “Parameterized Mode” is Improper The parameterized mode (0=OFF, 1=LUENBERGER) for the special NC controller velocity observer within the torque interface is improper. Range of values: [0, 1] Unit: 1 4527 17703 Parameter Velocity Observer: “Motor Torque Constant Kt or Kf” is Improper The parameter for the motor torque constant Kt (rotational motor) or Kf (linear motor) of the special NC controller velocity observer within the torque interface is improper. Range of values: [0.0 .. 100000.0] Unit:

Nm/A or N/A 4528 17704 Parameter Velocity Observer: “Motor Moment of Inertia JM” is Improper The parameter for the motor moment of inertia J of the M special NC controller velocity observer within the torque interface is improper. Range of values: [0.0001 .. 100000.0] Unit: kg cm^2 4529 17705 Parameter Velocity Observer: “Band Width f0” is Improper The parameter for the band width f of the special NC 0 controller velocity observer within the torque interface is improper. The band width has to be smaller than the reciprocal value of six times the NC cycle time (f Range of values: [0.0 .. 10000.0] Unit: Hz 452A 17706 Parameter Velocity Observer:

“Correction Factor kc” is Improper The parameter for the correction factor k of the special NC c controller velocity observer within the torque interface is improper. The correction factor k implements the relation c between current and acceleration or angular acceleration. Range of values: [0.0 .. 100.0] Unit: s 452B 17707 Parameter Velocity Observer: “Time Constant T for First Order Filter” is Improper The time constant T for the first order velocity filter (PID-T or 2 “Lead Lag”) of the specific NC controller velocity observer within the torque interface is improper. The correction factor k c implements the relation between current and acceleration or angular acceleration.

Range of values: [0.0 .. 100.0] Unit: s 452C 17708 Parameter Velocity Observer: “Amplitude Damping d for Second Order Filter” is Improper The high pass/ low pass amplitude damping d or d for the HP TP second order velocity filter (“Bi-Quad”) of the special NC controller velocity observer within the torque interface is improper. Range of values: [0.2 .. 10.0] Unit: 1 452D 17709 Parameter Velocity Observer: “Frequency fHP or Frequency fTP for Filters of Second Order” is Improper The high pass frequency f or the low pass frequency f for HP TP the second order velocity filter (“Bi-Quad”) of the specific NC controller velocity observer within the torque interface is improper. Range of values:

[0.0, .. 10000.0] Unit: Hz