beckhoff TS511x — 6.2.7 Drive Errors

Error Codes 6.2.7 Drive Errors TS511x 81 Version: 1.0 Error(Hex) Error(Dec) Error Type Description 4540 17728 Initialization "Controller initialization" Controller has not been initialized. Although the controller has been created, the rest of the initialization has not been performed (1. Initialization of controller, 2. Reset controller). 4541 17729 Address "Axis address" Controller does not know its axis, or the axis address has not been initialized. 4542 17730 Address "Drive address" Controller does not know its drive, or the drive address has not been initialized.

4550 17744 Monitoring "Following error monitoring (position)" With active following error monitoring (position) a following error exceedance has occurred, whose magnitude is greater than the following error window, and whose duration is longer than the parameterized following error filter time. 4551 17745 Monitoring "Following error monitoring (velocity)" With active following error monitoring (velocity) a velocity following error exceedance has occurred, whose magnitude is greater than the following error window, and whose duration is longer than the parameterized following error filter time.

45A0 17824 Monitoring "CONTROLERR RANGE AREA ASIDE" _ _ _ 45A1 17825 Monitoring "CONTROLERR RANGE AREA BSIDE" _ _ _ 45A2 17826 Monitoring "CONTROLERR RANGE QNENN" _ _ 45A3 17827 Monitoring "CONTROLERR RANGE PNENN" _ _ 45A4 17828 Monitoring "CONTROLERR RANGE AXISIDPRESP0" _ _ Error(hex) Error(dec) Error Type Description 4600 17920 Parameter ‘"Drive ID not allowed" The value for the drive ID is not allowed, e.g. because it has already been assigned, is less than or equal to zero, or is greater than 255. Value range: [1 ... 255] Unit: 1 4601 17921 Parameter ‘Drive type impermissible’ The value for the drive type is impermissible, since it is not defined. Value range: [1, 20] Unit:

1 4602 17922 Parameter ‘Drive operating mode impermissible’ The value for the drive operating mode is impermissible (mode 1: standard). Value range: [1] Unit: 1 4603 17923 Parameter "Motor polarity inverted?" The flag for the motor polarity is not allowed. Flag 0: Positive motor polarity flag 1: Negative motor polarity Value range: [0, 1] Unit: 1 4604 17924 Parameter ‘Drift compensation/speed offset (DAC offset)’ The value for the drift compensation (DAC offset) is impermissible. Value range: [-100.0, 100.0] Unit: e.g. m/min 4605 17925 Parameter ‘Reference speed (velocity pre-control)’ The value for the reference speed (also called velocity pilot control) is impermissible. Value range:

[0.0, 10000.0] Unit: e.g. m/min 4606 17926 Parameter ‘Reference output in percent’ The value for the reference output in percent is impermissible. The value 1.0 (100 %) usually corresponds to a voltage of 10.0 V. Value range: [0.0, 5.0] Unit: %