beckhoff TS511x — 6.2.7 Drive Errors

Error Codes TS511x 82 Version: 1.0 Error(hex) Error(dec) Error Type Description 4607 17927 Parameter ‘Quadrant compensation factor’ The value for the quadrant compensation factor is impermissible. Value range: [0.0, 100.0] Unit: 1 4608 17928 Parameter ‘Velocity reference point’ The value for the velocity reference point in percent is impermissible. The value 1.0 corresponds to 100 percent. Value range: [0.01, 1.0] Unit: % 4609 17929 Parameter ‘Output reference point’ The value for the output reference point in percent is impermissible. The value 1.0 corresponds to 100 percent. Value range: [0.01, 1.0] Unit:

% Error(hex) Error(dec) Error Type Description 460A 17930 Parameter ‘Minimum or maximum output limits (output limitation)’ The value for the minimum and/or maximum output limit is impermissible. This will happen if the range of values is exceeded, the maximum limit is smaller than the minimum limit, or the distance between the minimum and maximum limits is zero. The minimum limit is initially set to –1.0 (-100 percent) and the maximum limit to 1.0 (100 percent). Value range: [-1.0, 1.0] Unit: % 460B 17931 Parameter Parameter “Maximum Value for Output” is Improper The value for the maximum number of output digits of motion controllers (maximum output value) is improper.

According to the used interface (e.g. position, velocity or torque/current). Regarding a velocity interface it is often about a signed 16 bit output value (± 32767). Range of values: [0x000000FF .. 0xFFFFFFFF] Unit: INC or Digits 460C 17932 Parameter Parameter “Internal Drive Control Word” is Improper The value as Internal Drive Control Word for the NC is improper. In this control word information from the system manager to the NC is contained what is evaluated at the TC start of the NC. Range of values: [>0] Unit:

1 460D 17933 Parameter Parameter “Internal Timer for RESET Behavior of Motion Controller” is Improper The special parameter that influences the internal timing behavior between the NC motion controller and the IO motion controller is improper. Range of values: [>5] Unit: 1 (NC SAF Cycles) 460E 17934 Parameter Parameter “Master Motion Controller ID” is Improper The parameter “master motion controller ID” is improper for a further NC motion controller in slave mode. An additional NC motion controller in slave mode can be used if this usage is about the same motion controller device on that different NC information for e.g. different operation modes are joined (e.g.

velocity mode and torque mode). Note: This parameter is not accessible by the user directly, but can be influenced indirectly by the configuration of additional NC motion controllers below the NC axis. Range of values: [0 .. 255] Unit: 1