Error Codes TS511x 96 Version: 1.0 0x810B 33035 INVALIDDRIVEOPMODE Invalid drive operation mode active or requested (no bode plot mode) 0x810C 33036 INVALIDCONTEXT Invalid context for this command (mandatory task or windows context needed) 0x810D 33037 NOAXISINTERFACE Missing TCom axis interface (axis null pointer). There is no connection to the NC axis. Either no axis (or axis ID) has been parameterized, or the parameterized axis does not exist. 0x810E 33038 INPUTCYCLECOUNTER Invalid input cycle counter from IO drive (e.g. frozen). The cyclic drive data are backed up by an ‘InputCycleCounter’ during the bode plot recording.
This allows firstly the detection of an unexpected communication loss (keyword: LifeCounter) and secondly a check for temporal data consistency to be performed. Sample 1: This error can occur if the cycle time of the calling task is larger than the assumed drive cycle time (in this case, however, the error occurs right at the start of the recording). Sample 2: This error can occur if the calling task has real-time errors (e.g. the "Exceed Counter" of the task increments or the task has a lower priority, as is often the case, for example, with the PLC). In this case the error can also occur at any time during the recording. Sample 3:
This error can occur more frequently if the real-time load on the computer is quite high (>50 %). Note: Refer also to the corresponding AX5000 drive error code F440. 0x810F 33039 POSITIONMONITORING (=> NC Runtime Error) Position monitoring: Axis position is outside of the maximum allowed moving range. The axis has left the parameterized position range window, whereupon the recording was aborted and the NC axis was placed in the error state 0x810F (with standard NC error handling). The position range window acts symmetrically around the initial position of the axis (see also parameter description Position Monitoring Window). Typical error message in the logger: "BodePlot:
'Position Monitoring' error 0x%x because the actual position %f is above the maximum limit %f of the allowed position range (StartPos=%f, Window=%f)" 0x8110 33040 DRIVELIMITATIONDETECTE D Driver limitations detected (current or velocity limitations) which causes a nonlinear behavior and invalid results of the bode plot. A bode plot recording requires an approximately linear transmission link. If the speed or current is limited in the drive unit, however, this non-linear behavior is detected and the bode plot recording is aborted. Reasons for these limitations can be:
choosing too large an amplitude for the position, speed or torque interface, or an unsuitable choice of amplitude scaling mode (see also parameter description Amplitude Scaling Mode, Base Amplitude, Signal Amplitude).