Error Codes 6.2.12 Further Error Codes TS511x 97 Version: 1.0 Typical error message in the logger: "BodePlot: Sequence aborted with error 0x%x because the current limit of the drive has been exceeded (%d times) which causes a nonlinear behavior and invalid results of the bode plot" 0x8111 33041 LIFECOUNTERMONITORING (=> NC Runtime Error) Life counter monitoring (heartbeat): Lost of communication to GUI detected after watchdog timeout is elapsed. The graphical user interface from which the bode plot recording was started is no longer communicating with the bode plot driver in the expected rhythm (keyword: ‘Life Counter’).
Therefore the recording is terminated immediately and the NC axes are placed in the error state 0x8111 (with standard NC error handling). Possible reasons for this can be an operating interface crash or a major malfunction of the Windows context. Typical error message in the logger: "BodePlot: Sequence aborted with GUI Life Counter error 0x%x because the WatchDog timeout of %f s elapsed ('%s')" 0x8112 33042 NCERR BODEPLOT WCSTA _ _ TE WC state error (IO data working counter) IO working counter error (WC state), for example due to real-time errors, EtherCAT CRC errors or telegram failures, EtherCAT device not communicating (OP state), etc.
0x8113- 0x811F 33043- 33055 RESERVED Reserved area Error(Hex) Error(Dec) Error Type Description 0x8120 33056 Environment Invalid configuration for Object (e.g. in System Manager). 0x8121 33057 Environment Invalid environment for Object (e.g. TcCom- Object's Hierarchy or missing/faulty Objects). 0x8122 33058 Environment Incompatible Driver or Object. 0x8124 33060 Function Block Command execution does not terminate (e. g. MC Reset does not signal DONE). _ 0x8130 33072 Communicatio n Invalid ObjectID of Communication Target. 0x8131 33073 Communicatio n Communication Target expects Call in different Context. 0x8132 33074 Communicatio n Invalid State of Communication Target.
0x8134 33076 Communicatio n Communication with Communication Target cannot be established. 0x813b 33083 Parameter Transition Mode is invalid. 0x813c 33084 Parameter BufferMode is invalid. 0x813d 33085 Function Block Only one active Instance of Function Block per Group is allowed. 0x813e 33086 State Command is not allowed in current group state. 0x813f 33087 Function Block Slave cannot synchronize. The slave cannot reach the SlaveSyncPosition with the given dynamics. 0x8140 33088 Parameter Invalid value for one or more of the dynamic parameters (Acceleration, Deceleration, Jerk).