Configuration Signal-Parameters Signal-Parameters Conversion-Parameters Conversion-Parameters TS6120 17 Version: 1.2.0 Type Req./Opt. Description AutoCfgSymFile Optional full path and name of symbol-file to be included like "C:\Test\demo.sym" or "\\User1\Test\demo.sym" or "C: \User1\Test\demo.tpy" Type Req./Opt. Description SignalID Req unique ID-number which identifies this simulation-signal SignalDesc Optional SignalType Req 0 : Read Count 1 : Write Count 2 : Random 3 : Ramp 4 : Sine 5 : Square 6 : Triangle 7 : Step 8 : Reserver 9 : Step Read Count : incremented by one every time when the item is read Write Count : incremented by one every time when the item is written Random:
generates random value within the Amplitude range starting with Position Ramp, Sine, Square, Triangle, Step: (periodical signals) Their time behavior is influenced by Period and Phase parameters. Period specifies the signal frequency, while Phase moves the signal origin on the time axis Square and Triangle signal types have one more parameter: Ratio. Ratio defines Triangle signal steepness, or Square signal H/L proportions. NumSteps parameter of the Step signal defines a number of steps signal amplitude will be divided into.
NumSteps Optional, depends on Amplitude Optional, depends on Period Optional, depends on Phase Optional, depends on Position Optional, depends on Ratio Optional, depends on